Grip1 Mouse siRNA Oligo Duplex (Locus ID 74053)

CAT#: SR421916

Grip1 (Mouse) - 3 unique 27mer siRNA duplexes - 2 nmol each


Special offer: Get $100/€100 off this product. Use code: SR100

USD 430.00

2 Weeks*

Size
    • 2 nmol

Product Images

Other products for "Grip1"

Specifications

Product Data
Purity HPLC purified
Quality Control Tested by ESI-MS
Sequences Available with shipment
Components Grip1 (Mouse) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 74053)
Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmol
Included - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml
Stability One year from date of shipment when stored at -20°C.
Number of Transfections Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM).
Note Single siRNA duplex (10nmol) can be ordered.
Reference Data
RefSeq NM_001277292, NM_001277293, NM_001277294, NM_001277295, NM_028736, NM_130891, NM_133442, NR_102387, NM_001358809, NM_001358810, NM_001358811
Synonyms 4931400F03Rik; eb; GRIP
Summary This gene encodes a protein containing multiple PDZ (post synaptic density protein, Drosophila disc large tumor suppressor, and zonula occludens-1 protein) domains. The encoded protein acts as a mediator between cytoskeletal and membrane proteins, particularly in neuronal cells, and facilitates complex formation at the cell membrane. Mutation of this gene can cause embryonic lethality resulting from defects of the dermo-epidermal junction. Alternative splicing results in multiple transcript variants. [provided by RefSeq, Mar 2013]
Performance Guaranteed OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency.

For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required).

{0} Product Review(s)

0 Product Review(s) Submit review

Be the first one to submit a review

Product Citations

*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.