CD3E Mouse Monoclonal Antibody [Clone ID: M2AB]

CAT#: AM05170AC-N

CD3E mouse monoclonal antibody, clone M2AB, APC


USD 380.00

5 Days*

Size
    • 100 Tests

Product Images

Specifications

Product Data
Clone Name M2AB
Applications FC
Recommended Dilution Flow Cytometry.
This antibody is suitable for Monitoring of T cells subsets in peripheral blood, Characterization of subtypes of T cell leukemia's and lymphomas, Studies of AIDS/HIV virus infection, Analysis of CD3 complex related to the T cell antigen receptor.
Reactivities Human
Host Mouse
Isotype IgG1
Clonality Monoclonal
Immunogen CD3=Derived from the hybridization of mouse NS-1 myeloma celss with spleen cells from BALB/c mice immunized with human thymocytes.
Formulation PBS with 0.08% sodium azide as preservative and 0.2% protein carrier.
Label: APC
State: Liquid (sterile filtered) IgG fraction.
Label: analyzed in multi-color flow cytometry with instrumentsequipped with a second laser and proper filters. Laser excitation is at 633 nm with a Helium Neon (HeNe)laser or a 600-640 nm (633 nm) range for a Dye laser. Peak fluorescence emission is at 660 nm
Concentration lot specific
Conjugation APC
Storage Store the antibody (undiluted) at 2-8°C.
Do Not Freeze!
Stability Shelf life: One year from despatch.
Background The CD3 epitope is expressed on the epsilon chain of the CD3/T cell antigen receptor (TcR) complex.
CD3 is present on 65-85% of thymocytes and has a mitogenic effect on peripheral blood T cells.
Identification of human T cells expressing the 22-28,000 M.W. surface antigen.
Synonyms T3/Leu-4
Note Protocol: PBMC:
Add 10 ul of Antibody/10e6 PBMC in 100 ul PBS. Mix gently and incubate for 15 minutes at 2-8°C.
Wash twice with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze.

WHOLE BLOOD:
Add 10 ul of Antibody/100 ul of whole blood.
Mix gently and incubate for 15 minutes at room temperature 20°C.
Lyse the whole blood.
Wash once with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze.
See instrument manufacturer’s instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope.
Reference Data

{0} Product Review(s)

0 Product Review(s) Submit review

Be the first one to submit a review

Product Citations

*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.