CD28 Mouse Monoclonal Antibody [Clone ID: B-23]
Product Images
Specifications
Product Data | |
Clone Name | B-23 |
Applications | FC |
Recommended Dilution | Flow Cytometry. Monitoring of activated T cells in peripheral blood. Study of T lymphocyte cytokine function. Study of B cell activation. Study of Cell-adhesion molecules relating T and B lymphocytes. |
Reactivities | Human |
Host | Mouse |
Isotype | IgG1 |
Clonality | Monoclonal |
Immunogen | CD28=Derived from the hybridization of mouse Sp2/O-Ag14 myeloma cells with spleen cells of BALB/c mice immunized with the HPB-ALL T-cell line. |
Specificity | This antibody recats with CD28 receptor. |
Formulation | PBS containing 0.2% protein carrier and 0.08% Sodium Azide as preservative. Label: APC State: Liquid purified IgG fraction. |
Concentration | lot specific |
Conjugation | APC |
Storage | Store the antibody undiluted at 2-8°C. Do Not Freeze! |
Stability | Shelf life: One year from despatch. |
Database Link | |
Background | Anti-human CD28 binds the 44kDa MW cell surface protein on the surface of most T cells. CD28 acts as the ligand for the B7/BB-1 molecule on the surface of activated B cells. B7/BB-1 costimulates T cells through CD28, along with CD2 and CD3.CD28 antigen is a disulfide-linked homodimeric glycoprotein. The CD28 antigen is present on approximately 60%-80% T lymphocytes (95% of CD4 and 50% of CD8 lymphocytes). CD28 regulates the expression of cytokines by T cells, not only IL-2, but also IL-1 alpha and CSF-1, usually synthesized by accessory cells. CD28 functions as a cell adhesion molecule (CAM) for certain T cell subsets. |
Synonyms | TP44 |
Note | Protocol: PBMC: Add 10 ul of MAB/10e6 PBMC in 100 ul PBS. Mix gently and incubate for 15 minutes at 2-8°C. Wash twice with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. WHOLE BLOOD: Add 10 ul of MAB/100 ul of whole blood. Mix gently and incubate for 15 minutes at room temperature (20°C). Lyse the whole blood. Wash once with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. See instrument manufacturers instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope. |
Reference Data |
Documents
Product Manuals |
FAQs |
{0} Product Review(s)
0 Product Review(s)
Submit review
Be the first one to submit a review
Product Citations
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen
complexities in the preparation of your product. International customers may expect an additional 1-2 weeks
in shipping.